Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calculating the Equilibrium Constant02:46

Calculating the Equilibrium Constant

37.6K
The equilibrium constant for a reaction is calculated from the equilibrium concentrations (or pressures) of its reactants and products. If these concentrations are known, the calculation simply involves their substitution into the Kc expression.
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
37.6K
Calculating Standard Free Energy Changes02:49

Calculating Standard Free Energy Changes

24.7K
The free energy change for a reaction that occurs under the standard conditions of 1 bar pressure and at 298 K is called the standard free energy change. Since free energy is a state function, its value depends only on the conditions of the initial and final states of the system. A convenient and common approach to the calculation of free energy changes for physical and chemical reactions is by use of widely available compilations of standard state thermodynamic data. One method involves the...
24.7K
Calculating pH Changes in a Buffer Solution02:45

Calculating pH Changes in a Buffer Solution

57.6K
A buffer can prevent a sudden drop or increase in the pH of a solution after the addition of a strong acid or base up to its buffering capacity; however, such addition of a strong acid or base does result in the slight pH change of the solution. The small pH change can be calculated by determining the resulting change in the concentration of buffer components, i.e., a weak acid and its conjugate base or vice versa. The concentrations obtained using these stoichiometric calculations can be used...
57.6K
Numerical Calculations01:24

Numerical Calculations

1.1K
In engineering applications, the representation of the numerical value is critical. Presenting or reporting the answer is one of the essential parts of engineering practices. Numerical calculations are performed using handheld calculators or computers since numerically accurate answers are always preferred.
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...
1.1K
Net Torque Calculations01:19

Net Torque Calculations

11.2K
When a mechanic tries to remove a hex nut with a wrench, it is easier if the force is applied at the farthest end of the wrench handle. The lever arm is the distance from the pivot point (the hex nut in this case) to the person’s hand. If this distance is large, the torque is higher. Only the component of the force perpendicular to the lever arm contributes to the torque. Therefore, pushing the wrench perpendicular to the lever arm is more advantageous. If multiple people apply force to...
11.2K
Power01:08

Power

12.9K
The concept of work involves force and displacement; meanwhile, the work-energy theorem relates the net work done on a body to the difference in its kinetic energy, calculated between two points on its trajectory. While none of these quantities or relations involves time explicitly, we know that the time available to accomplish work is often just as important as the amount of work itself. For example, sprinters in a race may have achieved the same velocity at the finish, therefore,...
12.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exogenous Hormone Use as a Predictor of Central Serous Chorioretinopathy Recurrence: A Comparative Analysis of Observation Versus Low-Fluence Photodynamic Therapy.

Journal of vitreoretinal diseases·2025
Same author

Association of Patient Age with Response to Anti-Vascular Endothelial Growth Factor Agents for Treatment of Diabetic Macular Edema.

Retina (Philadelphia, Pa.)·2025
Same author

Impact of the COVID-19 pandemic on eye strain and dry eye symptoms.

The ocular surface·2021
Same author

Acute post-partum vision loss due to pilocytic astrocytoma.

American journal of ophthalmology case reports·2020
Same author

Multimodal Evaluation of Visual Function in Geographic Atrophy versus Normal Eyes.

Clinical ophthalmology (Auckland, N.Z.)·2020
Same author

Leukemic Infiltration of the Optic Nerve.

JCO oncology practice·2019

Related Experiment Video

Updated: Jan 21, 2026

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.0K

Updated practical intraocular lens power calculation after refractive surgery.

Gowtham Jonna1, Prabjot Channa

  • 1Albert Einstein College of Medicine, Montefiore Medical Center, Department of Ophthalmology and Visual Sciences, Bronx, NY, USA.

Current Opinion in Ophthalmology
|May 18, 2013
PubMed
Summary

Accurate intraocular lens (IOL) power calculation for cataract surgery in eyes with prior kerato-refractive surgery is now more achievable. Online IOL calculators offer efficient and reliable refractive outcomes, even without advanced equipment.

More Related Videos

Measuring the Behavioral Effects of Intraocular Scatter
05:10

Measuring the Behavioral Effects of Intraocular Scatter

Published on: February 18, 2021

3.9K
Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
11:49

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application

Published on: March 8, 2019

13.1K

Related Experiment Videos

Last Updated: Jan 21, 2026

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.0K
Measuring the Behavioral Effects of Intraocular Scatter
05:10

Measuring the Behavioral Effects of Intraocular Scatter

Published on: February 18, 2021

3.9K
Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
11:49

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application

Published on: March 8, 2019

13.1K

Area of Science:

  • Ophthalmology
  • Refractive Surgery
  • Cataract Surgery

Background:

  • Over 40 million individuals globally have had kerato-refractive surgery.
  • These patients often require cataract surgery, presenting challenges for achieving optimal refractive results.
  • Accurate intraocular lens (IOL) power calculation is crucial in these 'non-virgin' eyes.

Purpose of the Study:

  • To review practical and relevant methods for determining IOL power in eyes post-kerato-refractive surgery.
  • To highlight advancements and reliable options for accurate IOL power calculation.

Main Methods:

  • Review of current techniques and instrumentation for corneal power assessment.
  • Evaluation of online IOL calculators as practical tools.
  • Analysis of emerging literature on IOL power determination methods.

Main Results:

  • Modern corneal tomography instruments enhance accuracy in post-refractive eyes.
  • Online IOL calculators, like the American Society of Cataract and Refractive Surgery (ASCRS) calculator, are efficient and reliable.
  • Recent evidence validates the accuracy of these online calculators.

Conclusions:

  • Methods not requiring prior refractive data are increasingly supported.
  • Online IOL calculators provide user-friendly and effective solutions for accurate IOL power determination.