Related Experiment Video
Updated: May 11, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Circular external fixation for treatment of distal humerus fractures: case report
Louis Lewandowski1, Scott M Tintle, Carl Daniel
1Department of Orthopaedics, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA. Louis.R.Lewandowski.mil@health.mil
Abstract:
High-energy blasts can lead to complex intra-articular distal humerus fractures with extensive soft tissue loss, and treatment is fraught with complications. We describe 2 patients with such injuries treated successfully with the use of aggressive wound management followed by distal humerus fracture stabilization with a circular external fixator. We chose this circular external fixator over the Ilizarov frame because of our experience and success in the treatment of open tibia fractures with negligible malalignment and high union rate. This circular external fixator allows for indirect reduction of fracture fragments over time to improve final alignment with great control to fine-tune the reduction postoperatively. In our humerus cases, fracture union was achieved with good alignment and acceptable functional range of motion. Symptomatic heterotopic ossification did not develop despite the presence of multiple risk factors.