Related Experiment Video
Updated: May 11, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents
H Romm1, E Ainsbury, S Barnard
1Bundesamt fuer Strahlenschutz, Germany.
Abstract:
Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage in order to rapidly identify individuals who require clinical treatment. The manual dicentric assay is a highly suitable technique, but it is also very time consuming and requires well trained scorers. In the framework of the MULTIBIODOSE EU FP7 project, semi-automated dicentric scoring has been established in six European biodosimetry laboratories. Whole blood was irradiated with a Co-60 gamma source resulting in 8 different doses between 0 and 4.5Gy and then shipped to the six participating laboratories. To investigate two different scoring strategies, cell cultures were set up with short term (2-3h) or long term (24h) colcemid treatment. Three classifiers for automatic dicentric detection were applied, two of which were developed specifically for these two different culture techniques. The automation procedure included metaphase finding, capture of cells at high resolution and detection of dicentric candidates. The automatically detected dicentric candidates were then evaluated by a trained human scorer, which led to the term 'semi-automated' being applied to the analysis. The six participating laboratories established at least one semi-automated calibration curve each, using the appropriate classifier for their colcemid treatment time. There was no significant difference between the calibration curves established, regardless of the classifier used. The ratio of false positive to true positive dicentric candidates was dose dependent. The total staff effort required for analysing 150 metaphases using the semi-automated approach was 2 min as opposed to 60 min for manual scoring of 50 metaphases. Semi-automated dicentric scoring is a useful tool in a large scale radiation accident as it enables high throughput screening of samples for fast triage of potentially exposed individuals. Furthermore, the results from the participating laboratories were comparable which supports networking between laboratories for this assay.
More Related Videos
08:23An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
10:14Detection of Inter-chromosomal Stable Aberrations by Multiple Fluorescence In Situ Hybridization (mFISH) and Spectral Karyotyping (SKY) in Irradiated Mice
Published on: January 11, 2017