Related Experiment Video
Updated: May 11, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Generator pocket adhesions of cardiac leads: classification and correlation with transvenous lead extraction results
Hector Rodriguez Cetina Biefer1, David Hürlimann, Jürg Grünenfelder
1Clinic of Cardiac and Vascular Surgery.
Objectives:
Pacemaker (PM) and implantable cardioverter defibrillator (ICD) leads become encapsulated intravascularly and in the generator pocket by fibrotic adhesions that accumulate over time. These adhesions are responsible for the difficulty and risk of lead extraction procedures. We developed a classification scheme for pocket adhesions, classified all of the patients in the cohort, and examined the relationship between pocket adhesions and the outcome of the procedure.
Methods:
The classification of adhesions with respect to the intraoperative adhesion coverage was as followed: class 0 = adhesion free; class 1 ≤ 30% of adhesion coverage; class 2 = 30-60% of adhesion coverage; and class 3 ≥ 60% coverage. Patient data between December 2010 and March 2012 were collected. A total of 100 leads were extracted from 58 patients (1.7 ± 0.8 leads/patient); the mean lead implant duration was 78.5 ± 66.7 months, and the percentage of PM/ICD leads was 68% (n = 68)/32% (n = 32).
Results:
Distribution of the leads among classes: 0 = 10; 1 = 17; 2 = 25; and 3 = 48. Average implant times (months) according to the adhesion classes: 0 = 1.2 ± 0.4; 1 = 19.8 ± 19.2; 2 = 79.3 ± 46.6; and 3 = 115.1 ± 106.0 (correlation-coefficient 0.71; P ≤ 0.05). Average numbers of extraction tools used according to the adhesions: 0 = none; 1 = 0.4 ± 0.7; 2 = 1.6 ± 1.0; and 3 = 2.3 ± 1.2 (correlation coefficient = 0.67; P ≤ 0.05). Complete removal was achieved in 100% of the patients in classes 0 and 1; 96% in class 2 (n = 24); and 75% in class 3 (n = 36) (P ≤ 0.05). Mortality = 0.
Conclusions:
Extensive adhesions in the generator pocket predict the need for a higher number of extraction tools. High-grade pocket adhesions predict lower success rates with regard to complete lead extraction. Both findings suggest that the degree of pocket adhesions predicts the degree of intravascular adhesions.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Electrophysiology of Normal Cardiac Rhythm
Acute Coronary Syndrome III: Diagnostic Studies

