Related Experiment Video
Updated: May 11, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Quality and reproducibility of spirometry in COPD patients in a randomized trial (UPLIFT®)
W Janssens1, Y Liu, D Liu
1University Hospital Leuven, Leuven, Belgium. wim.janssens@uzleuven.be
Background:
This study explores spirometry quality and reproducibility in the Understanding Potential Long-term Impacts on Function with Tiotropium (UPLIFT(®)) trial.
Methods:
Four-year, randomized, double-blind, placebo-controlled, multicenter trial in 5993 patients with chronic obstructive pulmonary disease. Within-test variability of pre- and post-bronchodilator forced expiratory volume in 1 s (FEV(1)) was compared across study visits. Between-test variability of best pre- or post-FEV(1) values between two visits 6 months apart was compared at the start, middle and end of the trial.
Results:
Three or more acceptable maneuvers were obtained in 93% of visits. Within-test variability of pre- and post-FEV(1) (mean standard deviation: 0.092 and 0.098 L) decreased during the trial. Between-test variability also decreased: pre-FEV(1) (visit 3-5 = 0.141 ± 0.138 L; visit 9-11 = 0.129 ± 0.121 L; visit 17-19 = 0.121 ± 0.122 L); post-FEV(1) (0.139 ± 0.140, 0.126 ± 0.123, 0.121 ± 0.122 L, respectively), and was dependent on age, sex, smoking status and disease stage, but not on bronchodilator response or study treatment.
Conclusion:
Spirometry quality in UPLIFT(®) was good and improved during the trial. Between-test variability across patient subgroups suggests that relevant cut-offs for individual disease monitoring are difficult to establish.
Trial Registration Number:
NCT00144339.
More Related Videos
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-I: Introduction
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...