Related Experiment Video
Updated: May 11, 2026

Incorporating Target Protein Structure Flexibility and Dynamics in Computational Drug Discovery Using Ensemble-Based Docking Analysis
Published on: June 20, 2025
Optimization of 3D Poisson-Nernst-Planck model for fast evaluation of diverse protein channels
Witold Dyrka1, Maciej M Bartuzel, Malgorzata Kotulska
1Group of Bioinformatics and Biophysics of Nanopores, Institute of Biomedical Engineering and Instrumentation, Wroclaw University of Technology, Wroclaw, Poland.
Abstract:
We show the accuracy and applicability of our fast algorithmic implementation of a three-dimensional Poisson-Nernst-Planck (3D-PNP) flow model for characterizing different protein channels. Due to its high computational efficiency, our model can predict the full current-voltage characteristics of a channel within minutes, based on the experimental 3D structure of the channel or its computational model structure. Compared with other methods, such as Brownian dynamics, which currently needs a few weeks of the computational time, or even much more demanding molecular dynamics modeling, 3D-PNP is the only available method for a function-based evaluation of very numerous tentative structural channel models. Flow model tests of our algorithm and its optimal parametrization are provided for five native channels whose experimental structures are available in the protein data bank (PDB) in an open conductive state, and whose experimental current-voltage characteristics have been published. The channels represent very different geometric and structural properties, which makes it the widest test to date of the accuracy of 3D-PNP on real channels. We test whether the channel conductance, rectification, and charge selectivity obtained from the flow model, could be sufficiently sensitive to single-point mutations, related to unsignificant changes in the channel structure. Our results show that the classical 3D-PNP model, under proper parametrization, is able to achieve a qualitative agreement with experimental data for a majority of the tested characteristics and channels, including channels with narrow and irregular conductivity pores. We propose that although the standard PNP model cannot provide insight into complex physical phenomena due to its intrinsic limitations, its semiquantitative agreement is achievable for rectification and selectivity at a level sufficient for the bioinformatical purpose of selecting the best structural models with a great advantage of a very short computational time.
More Related Videos
Related Concept Videos
Protein Diffusion in the Membrane
Physiological Pharmacokinetic Models: Assumption with Protein Binding
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to the...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
G-Protein Gated Ion Channels
Sensory organs,...
Ligand-gated Ion Channels
Three Subfamilies of Ligand-gated Ion Channels
Ligand-gated ion channels fall into three subfamilies. The 'Cys-loop' includes the nicotinic acetylcholine receptors, γ-aminobutyric acid (GABA), glycine, and 5-hydroxytryptamine receptors. The second one is the 'Pore-loop' channels that include the...

