Epidural Intracranial Pressure Measurement in Rats Using a Fiber-optic Pressure Transducer
Published on: April 25, 2012
How to measure cerebrospinal fluid pressure invasively and noninvasively
Carol A Silverman1, Christopher J Linstrom
1Department of Otolaryngology, New York Eye and Ear Infirmary, New York, NY, USA.
Abstract:
We describe tympanic membrane displacement (TMD) testing for non-invasive estimation of intracranial pressure (ICP). With the TMD test, displacement of the tympanic membrane of the middle ear is recorded during elicitation of the acoustic middle-ear reflex (AR). Increased intracranial/perilymphatic pressure displaces the resting stapes footplate laterally so that TMD during the acoustic reflex is medial. Decreased intracranial/perilymphatic pressure displaces the baseline stapes footplate position medially (inward) so that TMD during the AR is lateral. The TMD typically is bidirectional when intracranial/perilymphatic pressure is normal. Discrepant findings have been reported for the sensitivity of the TMD test to ICP as the regression of TMD on invasive measurement of the ICP reveals substantial intersubject variability and overlap among patient and control groups. Large-sample research on TMD test performance in healthy persons and patients with various disorders affecting the ICP is needed using direct, invasive measures of the ICP as the gold standard. Research also is needed to examine whether non-invasive TMD testing can be used to investigate the trans-lamina cribrosa pressure difference in glaucoma.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Increased Intracranial Pressure ll: Pathophysiology
Increased Intracranial Pressure l: Introduction
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain.
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure