Maximal oxygen uptake (VO2max) during a graded maximal exercise test is the objective method to assess cardiorespiratory fitness. Maximal oxygen uptake testing is limited to only a few laboratories as it requires trained personnel and strenuous effort by the subject. At the population level, submaximal tests have been developed to derive VO2max indirectly based on heart rate based nomograms or it can be calculated using anthropometric measures. These heart rate based predicted standards have been developed for western population and are used routinely to predict VO2max in Indian population. In the present study VO2max was directly measured by maximal exercise test using a bicycle ergometer and was compared with VO2max derived by recovery heart rate in Queen's College step test (QCST) (PVO2max I) and with VO2max derived from Wasserman equation based on anthropometric parameters and age (PVO2max II) in a well defined age group of healthy male adults from New Delhi. The values of directly measured VO2max showed no significant correlation either with the estimated VO2max with QCST or with VO2max predicted by Wasserman equation. Bland and Altman method of approach for limit of agreement between VO2max and PVO2max I or PVO2max II revealed that the limits of agreement between directly measured VO2max and PVO2max I or PVO2max II was large indicating inapplicability of prediction equations of western population in the population under study. Thus it is evident that there is an urgent need to develop nomogram for Indian population, may be even for different ethnic sub-population in the country.
More Related Videos
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...