Related Experiment Video
Updated: May 10, 2026

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
Published on: June 19, 2018
Inaccuracy in the treatment of multiple-order diffraction by secondary-edge-source methods
1Applied Research in Acoustics LLC, 1222 4th Street SW, Washington, DC 20024-2302, USA. jason.e.summers@ariacoustics.com
Abstract:
Existing secondary-edge-source methods based on the Biot-Tolstoy solution for diffraction from an infinite wedge compute multiple-order diffraction by cascading the integration over secondary sources used to determine first-order diffraction from the edge. It is demonstrated here that this approach errs in some important cases because it neglects slope-diffraction contributions. This error is illustrated by considering the case of an infinite slit in a thin, hard screen. Comparisons with measurements for this case and analytical solutions for the case of a circular aperture in a thin, hard screen are used as a basis to gauge the magnitude of the error.
More Related Videos
11:48Microfluidic Chips for In Situ Crystal X-ray Diffraction and In Situ Dynamic Light Scattering for Serial Crystallography
Published on: April 24, 2018
07:24Quantitative Atomic-Site Analysis of Functional Dopants/Point Defects in Crystalline Materials by Electron-Channeling-Enhanced Microanalysis
Published on: May 10, 2021
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Determination of Crystal Structures
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...