Related Experiment Video
Updated: May 10, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Computed diffusion-weighted imaging of the prostate at 3 T: impact on image quality and tumour detection
Andrew B Rosenkrantz1, Hersh Chandarana, Nicole Hindman
1Department of Radiology, NYU Langone Medical Center, 550 First Avenue, New York, NY, 10016, USA, Andrew.Rosenkrantz@nyumc.org.
Objectives:
To investigate the impact of prostate computed diffusion-weighted imaging (DWI) on image quality and tumour detection.
Methods:
Forty-nine patients underwent 3-T magnetic resonance imaging using a pelvic phased-array coil before prostatectomy, including DWI with b values of 50 and 1,000 s/mm(2). Computed DW images with b value 1,500 s/mm(2) were generated from the lower b-value images. Directly acquired b-1,500 DW images were obtained in 39 patients. Two radiologists independently assessed DWI for image quality measures and location of the dominant lesion. A third radiologist measured tumour-to-peripheral-zone (PZ) contrast. Pathological findings from prostatectomy served as the reference standard.
Results:
Direct and computed b-1,500 DWI showed better suppression of benign prostate tissue than direct b-1,000 DWI for both readers (P ≤ 0.024). However, computed b-1,500 DWI showed less distortion and ghosting than direct b-1,000 and direct b-1,500 DWI for both readers (P ≤ 0.067). Direct and computed b-1,500 images showed better sensitivity and positive predictive value (PPV) for tumour detection than direct b-1,000 images for both readers (P ≤ 0.062), with no difference in sensitivity or PPV between direct and computed b-1,500 images (P ≥ 0.180). Tumour-to-PZ contrast was greater on computed b-1,500 than on either direct DWI set (P < 0.001).
Conclusion:
Computed DWI of the prostate using b value ≥1,000 s/mm(2) improves image quality and tumour detection compared with acquired standard b-value images.
Key Points:
• Diffusion weighted MRI is increasingly used for diagnosing and assessing prostate carcinoma. • Prostate computed DWI can extrapolate high b-value images from lower b values. • Computed DWI provides greater suppression of benign tissue than lower b-value images. • Computed DWI provides less distortion and artefacts than images using same b value. • Computed DWI provides better diagnostic performance than lower b-value images.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...

