Related Experiment Video
Updated: May 10, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common
Paul E Marik1, Rodrigo Cavallazzi
1Division of Pulmonary and Critical Care Medicine, Eastern Virginia Medical School, Norfolk, VA, USA. marikpe@evms.edu
Background:
Despite a previous meta-analysis that concluded that central venous pressure should not be used to make clinical decisions regarding fluid management, central venous pressure continues to be recommended for this purpose.
Aim:
To perform an updated meta-analysis incorporating recent studies that investigated indices predictive of fluid responsiveness. A priori subgroup analysis was planned according to the location where the study was performed (ICU or operating room).
Data Sources:
MEDLINE, EMBASE, Cochrane Register of Controlled Trials, and citation review of relevant primary and review articles.
Study Selection:
Clinical trials that reported the correlation coefficient or area under the receiver operating characteristic curve (AUC) between the central venous pressure and change in cardiac performance following an intervention that altered cardiac preload. From 191 articles screened, 43 studies met our inclusion criteria and were included for data extraction. The studies included human adult subjects, and included healthy controls (n = 1) and ICU (n = 22) and operating room (n = 20) patients.
Data Extraction:
Data were abstracted on study characteristics, patient population, baseline central venous pressure, the correlation coefficient, and/or the AUC between central venous pressure and change in stroke volume index/cardiac index and the percentage of fluid responders. Meta-analytic techniques were used to summarize the data.
Data Synthesis:
Overall 57% ± 13% of patients were fluid responders. The summary AUC was 0.56 (95% CI, 0.54-0.58) with no heterogenicity between studies. The summary AUC was 0.56 (95% CI, 0.52-0.60) for those studies done in the ICU and 0.56 (95% CI, 0.54-0.58) for those done in the operating room. The summary correlation coefficient between the baseline central venous pressure and change in stroke volume index/cardiac index was 0.18 (95% CI, 0.1-0.25), being 0.28 (95% CI, 0.16-0.40) in the ICU patients, and 0.11 (95% CI, 0.02-0.21) in the operating room patients.
Conclusions:
There are no data to support the widespread practice of using central venous pressure to guide fluid therapy. This approach to fluid resuscitation should be abandoned.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Hormonal Regulation of Blood Pressure
Epinephrine and Norepinephrine
The adrenal medulla releases epinephrine and norepinephrine, catecholamines that enhance and extend the sympathetic or "fight or flight" physiological response. These hormones escalate heart rate and the force of contraction while...
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...

