Objective:
Effort indicators are used to determine if neuropsychological test results are valid measures of a patient's cognitive abilities. The use of multiple effort measures is often advocated, but the false positive rate for multiple indicators depends on the number of measures used and the correlation among indicators. This study presents a meta-analysis of correlations among effort measures. False positive rates for multiple correlated indicators are then estimated using Monte Carlo simulations.
Methods:
a literature search of published studies identified 22 independent samples in which 407 correlations among 31 effort measures were available in 3564 participants with normal effort. Participants were patients with neurological or psychiatric disorders and healthy volunteers.
Results:
Meta-analysis showed a mean correlation among effort indicators of 0.31. Monte Carlo simulation based on a 15% false positive rate for individual indicators showed that, when 10 effort indicators are used together, 38% of patients with valid performance will be incorrectly identified as malingering if two failures is the diagnostic standard. Failure on five of 10 measures is required for a false positive rate of 10% or less. If five effort indicators are interpreted, a false positive rate of 19% results when two test failures are assumed to characterize poor effort and failure on three measures is required to maintain 90% specificity.
Conclusions:
False positive rates for effort tests increase significantly as the number of indicators that are administered is increased.
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Errors occurring during blood pressure monitoring
Several factors...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information with...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters assessment...
Unrealistic Optimism Bias