The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Comparison of techniques for double-lumen endobronchial intubation: 90° or 180° rotation during advancement through
Background:
During endobronchial intubation with a double-lumen endobronchial tube (DLT), the DLT is conventionally rotated through 90° when the bronchial tip is just past the vocal cords. This study was performed to investigate if rotation of the DLT through 180° decreases postoperative hoarseness, sore throat, or vocal cord injuries.
Methods:
Patients (n=164) undergoing thoracic surgery were randomized into two groups. Just after the bronchial tip passed the glottis, left-sided DLTs were rotated 90° (Group 90, n=84) or 180° (Group 180, n=80) counterclockwise and advanced. In the Group 180, DLTs were re-rotated 90° clockwise after the tracheal tip passed the glottis. Resistance during the advance of DLTs was assessed. Hoarseness and sore throat were evaluated for three postoperative days. Vocal cords were examined on the first postoperative day.
Results:
In nine patients allocated to Group 90, the DLT could not be advanced past the glottis because of severe resistance. There was less resistance to advancement of the DLT in Group 180 compared with Group 90 (P<0.001). The incidence of hoarseness was comparable between the two groups. Sore throat and vocal cord injuries occurred less frequently in Group 180 compared with Group 90 (20 vs 40%, P=0.008; 19 vs 47%, P=0.032).
Conclusions:
Rotation of a DLT through 180° facilitated its passage through the glottis and reduced the incidence of postoperative sore throat and vocal cord injuries.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.