Related Experiment Video
Updated: May 10, 2026

An Objective and Child-friendly Assessment of Arm Function by Using a 3-D Sensor
Published on: February 12, 2018
An assessment of hand volumetric and temperature changes during office related repetitive activities
U Chris Ugbolue1, Alexander C Nicol2
1Faculty of Science and Technology, School of Science, Institute for Clinical Exercise and Health Science, Hamilton Campus, Hamilton, Scotland, UK Department of Biomedical Engineering, University of Strathclyde, Wolfson Building, Glasgow, UK.
Background:
Hand usage and movement is routinely performed by all individuals daily irrespective of age. These movements can vary and can be repetitive in nature. Exposure of the hard and soft tissues of the hand to prolonged repetitive activities could contribute to the development of work related upper limb disorders (WRULD).
Objective:
Within the work setting, work related upper limb disorders (WRULDs) rank high in the United Kingdom (UK), second only to back complaints. This paper reports the amount of tendon travel and swelling that occurs in the hand during repetitive office activities associated with WRULDs.
Participants:
Nine healthy adults (five males; four females) participated in the study.
Methods:
A 30-minute laboratory-based simulated office activity that consisted of data entry, mouse clicking and dragging, and mouse scrolling tasks was performed. Participants wore a custom-made cost effective flexible electrogoniometric glove (FEG) as two experimental conditions were tested; namely, FEG - only, and FEG using a Splint (FEG - Splint).
Results:
The FEG - only condition produced a higher overall tendon travel compared to the FEG - Splint condition. Both hands presented no statistically significant differences in hand temperature (p > 0.05) and hand volume increments (p > 0.05) with respect to the FEG - only and FEG - Splint office activity experiments. All participants that showed a decrease in hand volumetric measurement produced final temperature measurements lower than initial temperature measurements taken at the commencement of the experiment. Based on participants' perception, the mouse scrolling task was deemed as most strenuous.
Conclusion:
The findings can help to advise patients on biomechanical 'risks' associated with repetitive activities.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...