Related Experiment Video
Updated: May 10, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Determination of mechanisms and parameters which affect radon entry into a room
1Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy st., 20, GSP-594, 620219 Yekaterinburg, Russia. vav@ecko.uran.ru
Abstract:
There are practically no direct techniques for measuring radon entry rate in the rooms. The suggested technique allows estimating such parameter under real conditions. The technique for radon diagnostic procedures including radon entry rate and air change rate assessment was proposed and tested in the field under various experimental conditions. The method consists of the continuous measurement of radon concentration, temperature and pressure difference between indoor and outdoor atmosphere. It was demonstrated that the study of dependence of radon entry rate on temperature difference ΔT between indoor and outdoor atmosphere allows to estimate the dominant radon entry mechanism - diffusion mechanism (absence of the dependence on ΔT) or convective (radon entry rate increase at ΔT increase). It was shown that simultaneous measurements of time series of radon concentration and pressure difference between building envelope and outdoor atmosphere allow assessing such room parameter as Effective Leakage Area. The approach applied in this paper to estimate the air change rate practically is not differing from tracer gas techniques when the constant gas entry rate is used. It was shown that radon could be used as kind of tracer gas to estimate the air change rate. Obtained measurement results for all buildings confirmed the seasonal variations of radon concentrations. A correlation of radon concentration and air change rate with outside temperature occurred in general.
Related Concept Videos
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Biological Effects of Radiation
Absorption of Radiation
Radioactive Decay and Radiometric Dating
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Arrhenius Plots
The Arrhenius equation can be used to...

