Related Experiment Video
Updated: May 9, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Evaluation of Tp-e interval and Tp-e/QT ratio in patients with non-dipper hypertension
1Department of Cardiology Yüksek İhtisas Education and Research Hospital , Bursa , Turkey and.
Aims:
Non-dipper hypertension is associated with increased cardiovascular morbidity and mortality. Several studies have suggested that the interval from the peak to the end of the electrocardiographic T wave (Tp-e) may correspond to the transmural dispersion of repolarization and that increased Tp-e interval and Tp-e/QT ratio are associated with malignant ventricular arrhythmias. The aim of this study was to evaluate ventricular repolarization by using Tp-e interval and Tp-e/QT ratio in patients with non-dipper hypertension.
Materials And Method:
This study included 80 hypertensive patients. Hypertensive patients were divided into two groups: 50 dipper patients (29 male, mean age 51.5 ± 8 years) and 30 non-dipper patients (17 male, mean age 50.6 ± 5.4 years). Tp-e interval and Tp-e/QT ratio were measured from the 12-lead electrocardiogram. These parameters were compared between groups.
Results:
No statistically significant difference was found between two groups in terms of basic characteristics. In electrocardiographic parameters analysis, QT dispersion (QTd) and corrected QTd were significantly increased in non-dipper patients compared to the dippers (39.4 ± 11.5 versus 27.3 ± 7.5 ms and 37.5 ± 9.5 versus 29.2 ± 6.5 ms, p = 0.001 and p = 0.01, respectively). Tp-e interval and Tp-e/QT ratio were also significantly higher in non-dipper patients (97.5 ± 11.2 versus 84.2 ± 8.3 ms and 0.23 ± 0.02 versus 0.17 ± 0.02, all p value <0.001).
Conclusion:
Our study revealed that QTd, Tp-e interval and Tp-e/QT ratio are prolonged in patients with non-dipper hypertension.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring pulse
Assessment of blood pressure in brachial artery(two-step method)