Quantitative radiographic imaging using a photostimulable phosphor system.

C E Floyd1, H G Chotas, J T Dobbins

  • 1Duke University Medical Center, Durham, North Carolina 27710.

Medical Physics
|May 1, 1990
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Feature and knowledge based analysis for reduction of false positives in the computerized detection of masses in screening mammography.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2007
Same author

Digital tomosynthesis of hand joints for arthritis assessment.

Medical physics·2003
Same author

Application of the mutual information criterion for feature selection in computer-aided diagnosis.

Medical physics·2002
Same author

Computerized classification of suspicious regions in chest radiographs using subregion Hotelling observers.

Medical physics·2002
Same author

A neural network approach to breast cancer diagnosis as a constraint satisfaction problem.

Medical physics·2001
Same author

Digital chest radiography with a solid-state flat-panel x-ray detector: contrast-detail evaluation with processed images printed on film hard copy.

Radiology·2001
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

This study assesses the accuracy of a Philips Computed Radiography (PCR) system for measuring X-ray exposure in diagnostic imaging. The PCR system demonstrates reliable quantitative X-ray exposure measurements, with accuracy between 1.6% and 5.9%.

Area of Science:

  • Medical Physics
  • Radiological Imaging
  • Diagnostic Radiology

Background:

  • Accurate X-ray exposure quantification is crucial for diagnostic radiography.
  • Photostimulable phosphor computed radiography (PCR) systems offer potential for quantitative imaging.

Purpose of the Study:

  • To evaluate the accuracy and reliability of a specific PCR system for quantitative X-ray exposure measurements.
  • To identify and assess factors influencing measurement accuracy in PCR systems.

Main Methods:

  • An exponential function was used to calibrate digital pixel values against X-ray exposure.
  • Investigated factors affecting accuracy: repeatability, background noise, plate sensitivity variations, latent image decay.
  • Calibration range: 5.1 x 10(-9) to 2.0 x 10(-5) C/kg.

Related Experiment Videos

Main Results:

  • Single imaging plate measurements showed accuracy between 1.6% and 4.2%.
  • Measurements involving multiple plates had an uncertainty between 5% and 5.9%.
  • Identified key factors influencing measurement precision and accuracy.

Conclusions:

  • The evaluated PCR system is suitable for quantitative X-ray exposure measurements in diagnostic radiography.
  • Understanding influencing factors is essential for optimizing accuracy in clinical applications.
  • The system provides a reliable tool for dose monitoring and quality assurance.