Related Experiment Video
Updated: May 9, 2026

Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
Development of unconstrained heartbeat and respiration measurement system with pneumatic flow
Yosuke Kurihara1, Kajiro Watanabe
1Department of Computer and Information Science, Faculty of Science and Technology, Seikei University, Musashino-shi, Tokyo 180-8633, Japan. yosuke-kurihara@st.seikei.ac.jp
Abstract:
The management of health through daily monitoring of heartbeat and respiration signals is of major importance for early diagnosis to prevent diseases of the respiratory and circulatory system. However, such daily health monitoring is possible only if the monitoring system is physically and psychologically noninvasive. In this paper, an unconstrained method of measuring heartbeat and respiration signals, by using a thermistor to measure the air flows from the air mattress to an air tube accompanying the subject's heartbeat and respiration, is proposed. The SN ratio with interference by opening and closing of a door as environmental noise was compared with that obtained by the conventional condenser microphone method. As a result, the SN ratios with the condenser microphone method were 26.6 ± 4.2 dB for heartbeat and 27.8 ± 3.0 dB for respiration, whereas with the proposed method they were 34.9 ± 3.1 dB and 42.1 ± 2.5 dB, respectively.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Related Concept Videos
Measurement of Blood Pressure
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...