Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples
05:17

Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples

Published on: July 28, 2016

Measuring myeloperoxidase activity in biological samples.

Benjamin Pulli1, Muhammad Ali, Reza Forghani

  • 1Center for Systems Biology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.

Plos One
|July 18, 2013
PubMed
Summary

A new, validated assay protocol provides specific and sensitive measurement of myeloperoxidase (MPO) activity in biological samples. This method distinguishes between extracellular MPO and intracellular MPO, a marker for neutrophil infiltration.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Circulating Extracellular Vesicles Reflect Dynamic Shifts in Liver Transcriptome Following Tumour Resection.

Cancers·2026
Same author

Differentiating aetiologies in perimesencephalic SAH: clinical insights into basilar artery perforator aneurysms.

Journal of neurology, neurosurgery, and psychiatry·2026
Same author

Woven Endobridge device for ruptured vs. unruptured aneurysms: insights from the WorldWideWEB study.

Neuroradiology·2026
Same author

Therapeutic Spp1 silencing in TREM2<sup>+</sup> cardiac macrophages suppresses atrial fibrillation.

Nature cardiovascular research·2026
Same author

Intra-Arterial Thrombolytic vs. Mechanical Thrombectomy in Distal Medium Middle Cerebral Artery Acute Ischemic Stroke: A Preliminary Multinational Multicenter Propensity Score-Matched Study.

Clinical neuroradiology·2026
Same author

Gradation of Prolonged Venous Transit on Perfusion Imaging Highlights the Association of Deep Venous Drainage Impairment with Unfavorable Functional Outcome in Successfully Reperfused Anterior Circulation Large-Vessel-Occlusion Stroke.

AJNR. American journal of neuroradiology·2026

Area of Science:

  • Biochemistry
  • Immunology
  • Pathology

Background:

  • Myeloperoxidase (MPO) is an enzyme implicated in various diseases.
  • Current MPO activity assays lack specificity, sensitivity, and uniformity.
  • Standardization is crucial for reliable MPO activity measurements in biological samples.

Purpose of the Study:

  • To establish and validate a robust MPO activity assay protocol.
  • To differentiate between extracellular and intracellular MPO activity.
  • To correlate MPO activity with disease markers and neutrophil content.

Main Methods:

  • Developed a protocol to isolate extra- and intracellular MPO from murine organs.
  • Employed antibody capture of MPO followed by ADHP assessment.
  • Validated the assay using MPO-knockout mice and disease models (multiple sclerosis, steatohepatitis, myocardial infarction).

More Related Videos

Quantifying Myeloperoxidase-DNA and Neutrophil Elastase-DNA Complexes from Neutrophil Extracellular Traps by Using a Modified Sandwich ELISA
07:18

Quantifying Myeloperoxidase-DNA and Neutrophil Elastase-DNA Complexes from Neutrophil Extracellular Traps by Using a Modified Sandwich ELISA

Published on: May 12, 2023

Related Experiment Videos

Last Updated: May 9, 2026

Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples
05:17

Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples

Published on: July 28, 2016

Quantifying Myeloperoxidase-DNA and Neutrophil Elastase-DNA Complexes from Neutrophil Extracellular Traps by Using a Modified Sandwich ELISA
07:18

Quantifying Myeloperoxidase-DNA and Neutrophil Elastase-DNA Complexes from Neutrophil Extracellular Traps by Using a Modified Sandwich ELISA

Published on: May 12, 2023

Main Results:

  • The validated protocol demonstrated high specificity and reproducibility for MPO activity assays.
  • The ADHP method showed high sensitivity across a broad range.
  • Intracellular MPO activity correlated significantly with tissue neutrophil content, serving as a marker for neutrophil infiltration.

Conclusions:

  • A highly specific and sensitive MPO activity assay protocol has been validated for use in biological samples.
  • The protocol allows for the assessment of both extracellular MPO activity (oxidative stress) and intracellular MPO activity (neutrophil infiltration).
  • This standardized method is recommended for all future MPO activity assays.