Related Experiment Video
Updated: May 9, 2026

Accumulation and Analysis of Cuprous Ions in a Copper Sulfate Plating Solution
Published on: March 20, 2019
Determination of trace amount of Cu2+ with a multi-responsive colorimetric and reversible chemosensor
Yong-Sheng Mi1, Zhong Cao, Ya-Ting Chen
1State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, P.R. China.
Abstract:
A multi-responsive sensor 1 was constructed by combining a ferrocene unit and a rhodamine block via a carbohydrazone bond. The sensor showed high selectivity toward Cu(2+) over other common metal ions in a wide pH range with excellent reversibility and rapid response. The obvious color change from colorless to pink upon the addition of Cu(2+) could make it a suitable 'naked-eye' indicator for Cu(2+). The detection limit (LOD) obtained was down to 2.0 nM and the association constant (Ka) was evaluated as 4.65 × 10(7) M(-1). The accuracy for detecting Cu(2+) in environmental river water was compared favorably with the traditional atomic absorption spectroscopy method (AAS). Finally, we proposed a reversible ring-opening mechanism (Off-On) of the rhodamine spirolactam induced by Cu(2+) binding and a 2 : 1 stoichiometric structure between 1 and Cu(2+).
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
06:36Preparation of Expanded Chitin Foams and their Use in the Removal of Aqueous Copper
Published on: February 27, 2021
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Controlled-Current Coulometry: Overview
Complexometric Titration: Overview
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Redox Titration: Overview