Related Experiment Video
Updated: May 9, 2026

Engineered Vascularized Muscle Flap
Published on: January 11, 2016
Prevention of necrosis of adjacent expanded flaps by surgical delay
Hainan Zhu1, Yun Xie, Feng Xie
1From the Plastic and Reconstructive Department, Shanghai Ninth People's Hospital Affiliated Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Abstract:
Although expanded flaps have been shown to survive longer than unexpanded flaps, flap necrosis still occurs, particularly when a deep back cut has been made. Overcautious design can avoid necrosis but leads to inefficient usage of the expanded flap. In this study, we tested a surgical delay method to prevent partial necrosis and maximize the use of the expanded flap. Ten patients with 13 expanders were included in this series. The surgical delay was performed 2 weeks before the final flap transfer. The survival of the delayed flaps was compared with that in previous cases without surgical delay. All 13 expanded flaps exhibited complete survival, which was significantly better than the 27.5% partial flap necrosis observed in nondelayed cases. Surgical delay can decrease the risk of necrosis in an expanded flap caused by a back cut and can thus maximize flap use.