Preventing deaths and injuries from house fires: an outcome evaluation of a community-based smoke alarm installation
Gregory R Istre1, Mary A McCoy, Billy J Moore
1Injury Prevention Center of Greater Dallas, , Dallas, Texas, USA.
Background:
Few studies have examined the impact of community-based smoke alarm (SA) distribution programmes on the occurrence of house fire-related deaths and injuries (HF-D/I).
Objective:
To determine whether the rate of HF-D/I differed for programme houses that had a SA installed through a community-based programme called Operation Installation, versus non-programme houses in the same census tracts that had not received such a SA.
Methods:
Teams of volunteers and firefighters canvassed houses in 36 high-risk target census tracts in Dallas, TX, between April 2001 and April 2011, and installed lithium-powered SAs in houses where residents were present and gave permission. We then followed incidence of HF-D/I among residents of the 8134 programme houses versus the 24 346 non-programme houses.
Results:
After a mean of 5.2 years of follow-up, the unadjusted HF-D/I rate was 68% lower among residents of programme houses versus non-programme houses (3.1 vs 9.6 per 100 000 population, respectively; rate ratio, 0.32; 95% CI 0.10 to 0.84). Multivariate analysis including several demographic variables showed that the adjusted HF-D/I rate in programme houses was 63% lower than non-programme houses. The programme was most effective in the first 5 years after SA installation, with declining difference in rates after the 6th year, probably due to SAs becoming non-functional during that time.
Conclusions:
This collaborative, community-based SA installation programme was effective at preventing deaths and injuries from house fires, but the duration of effectiveness was less than 10 years.
More Related Videos
06:39Electroencephalographic, Heart Rate, and Galvanic Skin Response Assessment for an Advertising Perception Study: Application to Antismoking Public Service Announcements
Published on: August 28, 2017
04:24A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Related Concept Videos
Household Wiring And Electrical Safety
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Levels of Health Promotion and Illness Prevention
In primary prevention, actions taken before disease onset prevent the disease from...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Coronary Artery Disease IV: Preventive Measures