Related Experiment Video
Updated: May 9, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Quantitative evaluation of apically extruded debris with different single-file systems: Reciproc, F360 and OneShape
S Bürklein1, S Benten, E Schäfer
1Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, Münster, Germany.
Aim:
To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system.
Methodology:
Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded.
Results:
Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05).
Conclusions:
Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation.