Related Experiment Video
Updated: May 9, 2026

Implantation of Inferior Vena Cava Interposition Graft in Mouse Model
Published on: June 4, 2014
Functional analysis in vivo of engineered valved venous conduit with decellularized matrix and two bone
Jian-Ming Yuan1, Shao-Hu Xiong1, Zhen Liu1
1Department of Anatomy, Second Military Medical University, Shanghai, People's Republic of China.
Abstract:
Tissue engineering has been considered a promising approach for creating grafts to replace autologous venous valves. Here, ovine bone marrow-derived endothelial progenitor cells (EPCs) and multipotent adult progenitor cells (MAPCs) were harvested and then loaded into decellularized venous matrix to create tissue-engineered (TE) valved vein. Subsequently, the ovine femoral veins containing the valve were removed and replaced by TE grafts or acellular matrix only. The morphology and function were analysed for up to 1 year by ultrasonography, angiography, H&E staining and scanning electron microscopy (SEM). The differentiation of seeded cells was traced immunofluorochemically. The results showed that decellularized venous matrix could initially and feebly attract endogenous cells, but failed afterwards and were insufficient to restore valve function. On the contrary, the seeded cells differentiated into endothelial cells (ECs) in vivo and formed a monolayer endothelium, and smooth muscle cells within the scaffold therefore produced TE grafts comparable to the native vein valve. This TE graft remained patent and sufficient after implantation into the venous circuit of the ovine lower extremity for at least 6 months. Unfortunately, cells seeded on the luminal surface and both sides of the leaflets lost their biological functions at 12 months, resulting in thrombosis formation and leading to complete occlusion of the TE grafts and impotent venous valves. These findings suggest that this TE valved venous conduit can function physiologically in vivo in the medium term. Before translating this TE venous valve into clinical practice, the durability should be improved and thrombogenicity should be suppressed. Copyright © 2016 John Wiley & Sons, Ltd.
More Related Videos
08:53The Arteriovenous (AV) Loop in a Small Animal Model to Study Angiogenesis and Vascularized Tissue Engineering
Published on: November 2, 2016
11:49Autologous Endothelial Progenitor Cell-Seeding Technology and Biocompatibility Testing For Cardiovascular Devices in Large Animal Model
Published on: September 9, 2011