Related Experiment Video
Updated: May 9, 2026

Reconstitution of Cell-cycle Oscillations in Microemulsions of Cell-free Xenopus Egg Extracts
Published on: September 27, 2018
High-throughput and long-term observation of compartmentalized biochemical oscillators
Koshi Hasatani1, Mathieu Leocmach, Anthony J Genot
1LIMMS/CNRS-IIS, University of Tokyo, Komaba 4-6-2 Meguro-ku, Tokyo, Japan. rondelez@iis.u-tokyo.ac.jp.
Abstract:
We report the splitting of an oscillating DNA circuit into ∼700 droplets with picoliter volumes. Upon incubation at constant temperature, the droplets display sustained oscillations that can be observed for more than a day. Superimposed to the bulk behaviour, we find two intriguing new phenomena - slow desynchronization between the compartments and kinematic spatial waves - and investigate their possible origin. This approach provides a route to study the influence of small volume effects in biology, and paves the way to technological applications of compartmentalized molecular programs controlling complex dynamics.