Related Experiment Video
Updated: May 9, 2026

Treatment of Ligament Constructs with Exercise-conditioned Serum: A Translational Tissue Engineering Model
Published on: June 11, 2017
Thickness of the human ligamentum flavum as a function of load: an in vitro experimental study
1Department of Orthopaedics, Sahlgren Hospital, Sweden.
Abstract:
Human cadaver spine specimens, consisting of the third and fourth lumbar vertebral laminae and the intervening ligamentum flavum, were studied. The specimens were loaded in axial traction with 1, 2, 4, and 8 kg respectively. To avoid contact deformation the thinning of the yellow ligament was recorded through an opto-electronic laser system. An average elongation of 6 mm was found at 8 kg of traction with a corresponding average thinning of 2 mm. The results indicated that the thickness changes of the ligamentum flavum might affect the dimensions of the lumbar spinal canal during, for example, normal changes in body posture.

