Related Experiment Video
Updated: May 9, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Objectively measured vs self-reported compliance during oral appliance therapy for sleep-disordered breathing
Marijke Dieltjens1, Marc J Braem1, Anneclaire V M T Vroegop2
1Department of Special Care Dentistry, Antwerp University Hospital, Edegem; Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
Background:
Assessment of the overall therapeutic effectiveness of oral appliance therapy can only be realized through objectively measured compliance. The aims of this study were to assess objectively measured compliance during oral appliance therapy at 1-year follow-up and to compare these data with self-reported use.
Methods:
Fifty-one eligible patients were enrolled in this 1-year prospective clinical study (men, 61%; mean age, 49 ± 10 years; apnea-hypopnea index, 18.0 ± 11.9 events/h sleep; BMI, 26.6 ± 4.1 kg/m²). Objective compliance during oral appliance therapy at 1-year follow-up was assessed with a microsensor thermometer. Subjective compliance was assessed by self-report. Patients with a mean objectively measured use of ≥ 4 h/night on 70% of nights monitored were considered regular users. The mean disease alleviation was calculated as a measure of overall therapeutic effectiveness.
Results:
High agreement between objective and subjective compliance data at 1-year follow-up was reported (intraclass correlation coefficient, 0.8; 95% CI, 0.5-0.9), showing a mean subjective overestimation of 30 min (95% CI, -3.1 to 1.9; P = .02). The discontinuation rate at 1-year follow-up was 9.8%. The objective mean use rate was 6.4 ± 1.7 h/night at 1-year follow-up in continuing users, with a regular use rate of 83%. The mean disease alleviation was 54.9%.
Conclusions:
This study is the first to our knowledge to report the 1-year results of objectively measured compliance during oral appliance therapy. In addition, a high agreement between objective and subjective compliance data were reported, with a mean subjective overestimation of 30 min.
Trial Registry:
ClinicalTrials.gov; No.: NCT01284881; URL: www.clinicaltrials.gov.
More Related Videos
07:32Measuring Maxillary Posterior Tooth Movement: A Model Assessment using Palatal and Dental Superimposition
Published on: February 23, 2024
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Blind Procedures
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Sleep Apnea
The condition is more prevalent among...