On Artifact-Free Projection Overlaps in Multi-Pinhole Tomographic Imaging
Abstract:
In multi-pinhole SPECT, overlapping the projections from different pinholes has been used to increase sensitivity. However, the prevailing view is that the overall quality of the reconstructed image is not improved by the overlaps in the projections. It is often stated in literatures that overlaps introduce ambiguous information, which can lead to nonuniqueness of solution for the inverse problem, and thus artifacts are introduced in the reconstructed image. On the other hand, contrary to the prevailing view, a recent study on slit-slat collimators shows that artifacts can be removed with the "help" of an extra complete nonoverlapped projection data set. In this paper, two types of artifact-free projection overlaps are defined in general, and the criteria for designing artifact-free multi-pinhole systems with overlaps are proposed. It is shown that once the criteria are satisfied, the solution of the inverse problem is unique, and thus no artifact is expected in the reconstructed image. Via extensive simulation study, various artifact-free overlapping multi-pinhole systems are designed and validated. It is shown that overlaps in the artifact-free systems can improve contrast-to-noise ratio (CNR). With a proper design, the CNR for an artifact-free overlapping system can be significantly higher than that for the corresponding nonoverlapping system. The improved image quality is also confirmed with noisy reconstructions.
More Related Videos
07:13Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities
Published on: October 27, 2023
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...