Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex
Geoffrey Lee1, Saurabh Kumar, Andrew Teh
1The Department of Cardiology, The Royal Melbourne Hospital, Melbourne, Australia.
Objectives:
To characterize the nature of atrial fibrillation (AF) activation in human persistent AF (PerAF) using modern tools including activation, directionality analyses, complex-fractionated electrogram, and spectral information.
Background:
The mechanism of PerAF in humans is uncertain.
Methods And Results:
High-density epicardial mapping (128 electrodes/6.75 cm(2)) of the posterior LA wall (PLAW), LA and RA appendage (LAA, RAA), and RSPV-LA junction was performed in 18 patients with PerAF undergoing open heart surgery. Continuous 10 s recordings were analysed offline. Activation patterns were characterized into four subtypes (i) wavefronts (broad or multiple), (ii) rotational circuits (≥2 rotations of 360°), (iii) focal sources with centrifugal activation of the entire mapping area, or (iv) disorganized activity [isolated chaotic activation(s) that propagate ≤3 bipoles or activation(s) that occur as isolated beats dissociated from the activation of adjacent bipole sites]. Activation at a total of 36 regions were analysed (14 PLAW, 3 RSPV-LA, 12 LAA, and 7 RAA) creating a database of 2904 activation patterns. In the majority of maps, activation patterns were highly heterogeneous with multiple unstable activation patterns transitioning from one to another during each recording. A mean of 3.8 ± 1.6 activation subtypes was seen per map. The most common patterns seen were multiple wavefronts (56.2 ± 32%) and disorganized activity (24.2 ± 30.3%). Only 2 of 36 maps (5.5%) showed a single stable activation pattern throughout the 10-s period. These were stable planar wavefronts. Three transient rotational circuits were observed. Two of the transient circuits were located in the posterior left atrium, while the third was located on the anterior surface of the LAA. Focal activations accounted for 11.3 ± 14.2% of activations and were all short-lived (≤2 beats), with no site demonstrating sustained focal activity.
Conclusion:
Human long-lasting PerAF is characterized by heterogeneous and unstable patterns of activation including wavefronts, transient rotational circuits, and disorganized activity.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Dysrhythmias III: Characteristics of Dysrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrophysiology of Normal Cardiac Rhythm