Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Three-Dimensional Microscopy in Microbiology01:28

Three-Dimensional Microscopy in Microbiology

Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Using Principal Components Analysis to Visualize Motion and Mitigate Artifacts in Dynamic Optical Coherence Tomography.

Journal of biophotonics·2026
Same author

Balanced-detection visible optical coherence tomography with a low-noise supercontinuum laser.

Biomedical optics express·2025
Same author

828 kHz retinal imaging with an 840 nm Fourier domain mode locked laser.

Biomedical optics express·2024
Same author

Effect of an Anaerobic Fermentation Process on 3D-Printed PLA Materials of a Biogas-Generating Reactor.

Materials (Basel, Switzerland)·2022
Same author

Enhanced resolution optoacoustic microscopy using a picosecond high repetition rate Q-switched microchip laser.

Journal of biomedical optics·2022
Same author

Two octaves spanning photoacoustic microscopy.

Scientific reports·2022

Related Experiment Video

Updated: May 8, 2026

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
12:54

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

Published on: October 2, 2021

Master-slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence

Adrian Gh Podoleanu1, Adrian Bradu

  • 1Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK. ap11@kent.ac.uk

Optics Express
|August 14, 2013
PubMed
Summary
This summary is machine-generated.

A new Master-Slave Interferometry (MSI) method overcomes limitations in spectral domain interferometry (SDI) for optical coherence tomography (OCT). This innovation enables direct en-face cuts and parallel processing for advanced 3D imaging.

More Related Videos

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

Published on: August 4, 2018

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Published on: January 15, 2013

Related Experiment Videos

Last Updated: May 8, 2026

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
12:54

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

Published on: October 2, 2021

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

Published on: August 4, 2018

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Published on: January 15, 2013

Area of Science:

  • Optical Physics
  • Biomedical Imaging
  • Interferometry

Background:

  • Conventional spectral domain interferometry (SDI) requires data linearization, limiting its application in 3D optical coherence tomography (OCT).
  • Existing SDI methods for OCT cannot produce direct en-face cross-sections, hindering comprehensive 3D visualization.
  • These limitations restrict the speed and cost-effectiveness of high-resolution 3D OCT imaging.

Purpose of the Study:

  • To introduce a novel SDI method, Master-Slave Interferometry (MSI), that overcomes the disadvantages of conventional SDI techniques.
  • To enable direct en-face cuts and parallel processing capabilities in OCT systems.
  • To reduce the cost and increase the speed of producing en-face OCT images for advanced applications.

Main Methods:

  • Developed a novel Master-Slave Interferometry (MSI) approach, replacing the serial signal acquisition of conventional SDI.
  • Implemented a slave interferometer to acquire signals based on optical path difference (OPD) values determined by a master interferometer.
  • Designed an MSI setup that generates multiple signals, one for each OPD point within the investigated object.

Main Results:

  • The MSI method eliminates the need for data linearization, simplifying OCT system processing.
  • MSI enables direct en-face OCT imaging, overcoming a key limitation of conventional SDI.
  • The parallel nature of MSI allows for parallel sensing and signal processing, enhancing 3D OCT capabilities.

Conclusions:

  • The novel MSI method significantly advances SDI techniques for OCT applications.
  • MSI facilitates high-resolution medical imaging and microscopy of biosamples through improved 3D visualization.
  • This approach offers potential for lower-cost OCT systems and faster en-face image generation compared to conventional SDI.