Related Experiment Video
Updated: May 8, 2026

An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
Repositioning endotracheal tubes in the intensive care unit: depth changes poorly correlate with postrepositioning
Ming-Li Wang1, Kevin M Schuster, Bishwajit Bhattacharya
1Section of Trauma, Surgical Critical Care and Surgical Emergencies, Department of Surgery, Yale School of Medicine, New Haven, Connecticut 06520-8062, USA.
Background:
Suboptimal positioning of endotracheal tubes (ETs) is often identified on routine chest radiographs prompting adjustment. The accuracy of ET adjustments based on tube measurement markings at the incisors has not been reported.
Methods:
We performed a 1-year prospective observational study of all surgical intensive care unit patients requiring repositioning of their ET based on chest x-ray (CXR) study. The ET was repositioned by a respiratory therapist using tube markings at the incisors, and follow-up CXR images were obtained within 2 hours. ET tube locations were compared with the planned intervention. Mean, median, interquartile range (IQR) and [chi]2 results are reported.
Results:
Fifty-five patients met inclusion criteria and had a complete set of data (80% male). ET advancement was the most commonly required intervention (80%). For advancement, the median starting position was 7.10 cm (IQR, 2.20 cm) from the carina, with a median planned advancement of 2.00 cm. The actual advancement was a median of 1.15 cm, achieving 57.5% of the goal. Patients requiring ET withdrawal were more likely female (8 of 11, p < 0.001). For the withdrawal group, the median starting position was 0.70 cm (IQR, 1.05 cm) from the carina with a planned median withdrawal of 2.00 cm (IQR, 0.75 cm). The actual withdrawal was a median of 1.00 cm, achieving 50.0% of the goal. Overall, the mean difference between the planned and actual intervention was 1.55 cm (95% confidence interval, 1.16-1.95 cm) differing by a mean of 40% from the planned intervention (95% confidence interval, 29.0-51.0%). There was no correlation between the original location or the planned intervention and the accuracy of the intervention. In three cases, the ET moved opposite of the planned intervention.
Conclusion:
ET repositioning based on measurement at the incisors is inaccurate and the magnitude of the intervention does not correlate with the degree of error. Repositioning of ETs based on measurements at the incisors should be abandoned, or follow-up CXR images should be obtained.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...