Generation of a Chronic Obstructive Pulmonary Disease Model in Mice by Repeated Ozone Exposure
Published on: August 25, 2017
Ozone inhalation effects in females varying widely in lung size: comparison with males
1Department of Physical Education, University of California, Davis 95616.
Abstract:
It has been suggested that lung size accounts for observed gender differences in responsiveness to the same total inhaled dose of O3. To test the hypothesis that lung size is a determinant of magnitude of response within a gender, two groups of 14 healthy young adult females differing significantly in forced vital capacity [FVC; i.e., small-lung group mean = 3.74 liters (range 3.2-4.0) and large-lung group mean = 5.11 liters (range 4.5-6.2] were exposed for 1 h to filtered air (FA) and to 0.18 and 0.30 ppm O3. On each occasion, subjects exercised continuously on a cycle ergometer at a work rate that elicited a mean minute ventilation of approximately 47 l/min. For the small-lung group [mean total lung capacity (TLC) = 4.52 liters] exercise O2 uptake was 67% of maximal O2 uptake (VO2max), and that for the large-lung group (TLC 6.37 liters) was 61% of VO2max. Statistical analysis revealed significant decrements for both groups in FVC, forced expiratory volume in 1 s (FEV1.0), and forced expiratory flow rate in the middle half of FVC on exposure to 0.18 and 0.30 ppm O3. Exercise respiratory frequency increased, and tidal volume decreased significantly in both groups in response to 0.18 and 0.30 ppm O3 exposure. On exposure to 0.30 ppm O3, the number of individual subjective symptoms reported and their severity were significantly greater for both groups than those reported for the FA and 0.18 ppm O3 exposures. Both groups evidenced similar percent changes in pulmonary function and exercise ventilation response, and in subjective symptom response.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
External and Internal Respiration
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features