Aim:
This aim of this study was to evaluate the number of bacteria extruded apically during root canal preparation using Four Rotary instrumentation techniques.
Materials And Methods:
A total of 50 extracted mandibular premolars were selected, access cavities prepared and inserted in to rubber stoppers of 10 mL glass vial. Root canals were contaminated with a suspension of Enterococcus faecalis (E. faecalis) American Type Culture Collection (ATCC) 29212 and incubated for 24 h at 37°C. Debris extruded from the apical foramen during instrumentation was collected into vials. The numbers of Colony-forming units were determined for each sample.
Statistical Analysis:
The data obtained were analyzed using the one-way ANOVA followed by post-hoc tukey's test with a P = 0.05 as the level for statistical significance.
Results:
Results suggested a statistically significant difference in the number of colony forming units between four experimental rotary Nickel-Titanium instrumentation groups (P < 0.001).
Conclusion: