Liquid chromatography/tandem mass spectrometry method for quantitation of cremophor el and its applications
V Vijaya Bhaskar1, Anil Middha
1Department of Pharmacy, Jagadishprasad Jhabermal Tibrewala University, Vidyanagari, Jhunjhunu, Rajasthan 333001, India.
Abstract:
A rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed on C18 column (XBridge, 50 × 4.6 mm, 3.5 μ m). The most abundant molecular ions corresponding to PEG oligomers at m/z 828, 872, 916 and 960 with daughter ion at m/z 89 were selected for multiple reaction monitoring (MRM) in electrospray mode of ionisation. Plasma concentrations of CrEL were quantified after administration through oral and intravenous routes in male sprague dawley rats at a dose of 0.26 g/kg. The standard curve was linear (0.9972) over the concentration range of 1.00 to 200 μ g/mL. The lower limit of quantitation for CrEL was 1.00 μ g/mL using 50 μ L plasma. The coefficient of variation and relative error for inter and intra assay at three QC levels were 0.69 to 9.21 and -7.60 to 4.74 respectively. A novel proposal was conveyed to the scientific community, where formulation excipient can be analysed as qualifier in the analysis of NCEs to address the spiky plasma concentration profiles.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
Related Concept Videos
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
