Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 8, 2026

High-throughput Protein Expression Generator Using a Microfluidic Platform
09:26

High-throughput Protein Expression Generator Using a Microfluidic Platform

Published on: August 23, 2012

Protein-DNA force assay in a microfluidic format.

Marcus Otten1, Philip Wolf, Hermann E Gaub

  • 1Lehrstuhl für Angewandte Physik and Center for Nanoscience (CeNS), Ludwig-Maximilians-Universität, Amalienstrasse 54, 80799 Munich, Germany.

Lab on a Chip
|August 30, 2013
PubMed
Summary

This study introduces a microfluidic molecular force assay (MFA) for studying protein-DNA interactions. The novel chip design enables quantitative on-chip force measurements, advancing gene regulation and DNA repair research.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Evidence-Based Recommendations for Geriatric Trauma Care: Systematic Review and AI-Assisted Consolidation of Clinical Practice Guidelines Between 2016 and 2021.

Annals of surgery open : perspectives of surgical history, education, and clinical approaches·2025
Same author

Effectiveness of peer support for people with severe mental health conditions in high-, middle- and low-income countries: multicentre randomised controlled trial.

The British journal of psychiatry : the journal of mental science·2025
Same author

SURGE-ahead postoperative delirium prediction: external validation and open-source library.

European geriatric medicine·2025
Same author

Measuring fidelity to manualised peer support for people with severe mental health conditions: development and psychometric evaluation of the UPSIDES fidelity scale.

BMC psychiatry·2024
Same author

Single-molecule force stability of the SARS-CoV-2-ACE2 interface in variants-of-concern.

Nature nanotechnology·2023
Same author

A tethered ligand assay to probe SARS-CoV-2:ACE2 interactions.

Proceedings of the National Academy of Sciences of the United States of America·2022

Area of Science:

  • Biochemistry and Molecular Biology
  • Biophysics
  • Microfluidics and Lab-on-a-Chip Technology

Background:

  • Protein-DNA interactions are crucial for fundamental biological processes like gene regulation and DNA repair.
  • The molecular force assay (MFA) is a key technique for studying these interactions, particularly dissociation kinetics.
  • Microfluidic platforms offer advantages in parallelization, reduced sample volume, reproducibility, and cost-effectiveness.

Purpose of the Study:

  • To integrate microfluidic technology with molecular force assays for enhanced protein-DNA interaction studies.
  • To present, characterize, validate, and apply a novel microfluidic molecular force assay (MFA) using the MITOMI chip.
  • To develop and validate an alternative confocal fluorescence microscopy readout for this assay.

Main Methods:

More Related Videos

Multiplexed Single-molecule Force Proteolysis Measurements Using Magnetic Tweezers
10:08

Multiplexed Single-molecule Force Proteolysis Measurements Using Magnetic Tweezers

Published on: July 25, 2012

Use of Dual Optical Tweezers and Microfluidics for Single-Molecule Studies
06:53

Use of Dual Optical Tweezers and Microfluidics for Single-Molecule Studies

Published on: November 18, 2022

Related Experiment Videos

Last Updated: May 8, 2026

High-throughput Protein Expression Generator Using a Microfluidic Platform
09:26

High-throughput Protein Expression Generator Using a Microfluidic Platform

Published on: August 23, 2012

Multiplexed Single-molecule Force Proteolysis Measurements Using Magnetic Tweezers
10:08

Multiplexed Single-molecule Force Proteolysis Measurements Using Magnetic Tweezers

Published on: July 25, 2012

Use of Dual Optical Tweezers and Microfluidics for Single-Molecule Studies
06:53

Use of Dual Optical Tweezers and Microfluidics for Single-Molecule Studies

Published on: November 18, 2022

  • Development of a microfluidic lab-on-a-chip system integrating MFA principles.
  • Utilization of the established MITOMI chip design for a novel application.
  • Implementation and validation of a confocal fluorescence microscopy readout and analysis method.
  • Application of the assay for multiplexing, including EcoRI binding characterization.

Main Results:

  • Successful integration of microfluidics with MFA, creating a novel assay.
  • Validation of the integrated method and the confocal fluorescence microscopy readout.
  • Demonstration of multiplexing capabilities with the detection and characterization of EcoRI binding.
  • Establishment of a platform for quantitative on-chip force measurements.

Conclusions:

  • The developed microfluidic MFA provides a powerful platform for quantitative on-chip force measurements of protein-DNA interactions.
  • This technology is suitable for integration with DNA micro-spotting and in vitro expression for high-throughput studies.
  • The method advances the understanding of gene regulation, DNA repair, and immune response mechanisms.