Background:
Nosocomial infections caused by multidrug-resistant organisms are commonly associated with longer hospital stays up to 12 to 18 days and annual estimated costs of $5.7 billion to $6.8 billion. One common mode of transmission is cross-contamination between patients and providers via surface contaminants on devices such as telemetry systems.
Objectives:
To determine the effect of a cleaning protocol on colonization of surface contaminants on electrocardiographic telemetry systems in 4 cardiovascular step-down units and to compare colonization in medical vs surgical units.
Methods:
A prospective, randomized, case-controlled study (the Descriptive Evaluation of Electrocardiographic Telemetry Pathogens [DEET] study) was designed to evaluate microbial colonization on telemetry systems before and after cleaning with sodium hypochlorite wipes. Each randomly selected telemetry system served as its own control. Nurses used a standardized culture technique recommended by personnel in infection control. Colonization before and after cleaning was analyzed by using the McNemar test and frequency tables. A standard cost-comparison analysis was conducted.
Results:
A total of 30 telemetry systems in medical units and 29 in surgical units were evaluated; 41 telemetry systems (69%) were colonized before the intervention, and 14 (24%) were colonized after it (P < .001). Before cleaning, surface organisms were present in 14 instances (35%) in surgical units and in 27 instances (66%) in medical units (P < .001). The cleaning strategy was cost-effective.
Conclusions:
The cleaning intervention was effective, and cost-comparison analysis supported implementing a cleaning strategy for reusable leads rather than investing in disposable leads.
Related Concept Videos
Endocarditis III: Medical Management
Development of the Oral Microbiota
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Endocarditis I: Introduction
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...