Automatic determination of validity of input data used in ellipsoid fitting MARG calibration algorithms

Alberto Olivares1, Gonzalo Ruiz-Garcia, Gonzalo Olivares

  • 1Department of Signal Theory, Telematics and Communications, CITIC-University of Granada, Granada, Spain. aolivares@ugr.es

Sensors (Basel, Switzerland)
|September 10, 2013
PubMed

Related Concept Videos

Geoid and Ellipsoid01:28

Geoid and Ellipsoid

The Earth's shape is best described as an ellipsoid, a slightly flattened sphere created by rotating an ellipse around its minor axis. This flattening results in the polar axis being about 21 kilometers shorter than the equatorial axis. In contrast, the geoid represents the Earth's gravitational shape and aligns with the mean sea level (MSL). The geoid is an irregular equipotential surface where gravity is perpendicular at every point. Variations in Earth's mass distribution cause geoid...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling01:26

Influence of Earth's Curvature and Atmospheric Refraction on Leveling

During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance. Over a...