Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Extraction: Partition and Distribution Coefficients01:14

Extraction: Partition and Distribution Coefficients

The distribution law or Nernst's distribution law is the law that governs the distribution of a solute between two immiscible solvents. This law, also known as the partition law, states that if a solute is added to the mixture of two immiscible solvents at a constant temperature, the solute is distributed between the two solvents in such a way that the ratio of solute concentrations in the solvents remains constant at equilibrium.
For extracting a solute from an aqueous phase into an organic...
Extraction: Advanced Methods00:56

Extraction: Advanced Methods

Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is formed in...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Mean Absolute Deviation01:13

Mean Absolute Deviation

The mean absolute deviation is also a measure of the variability of data in a sample. It is the absolute value of the average difference between the data values and the mean.
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Correction: SIRT7 activates p53 by enhancing PCAF-mediated MDM2 degradation to arrest the cell cycle.

Oncogene·2026
Same author

PHF20 stabilizes the GAS7-F-actin axis to drive DNA damage repair and chemoresistance in cutaneous squamous cell carcinoma.

Cell death & disease·2026
Same author

CT-based radiomics to predict peri-device leakage after left atrial appendage closure.

BMC medical imaging·2026
Same author

High-fidelity image transmission and reconstruction through multimode fiber using OAM modes and deep learning.

Optics express·2026
Same author

Preliminary Developmental Safety Assessment of Allylestrenol in Pregnant SD Rats: Evaluation of F0 and Early F1 Generational Endpoints.

Drug design, development and therapy·2026
Same author

Supramolecular antioxidant conductive injectable hydrogel encapsulating L-arginine for synergistic modulation of myocardial infarction.

Journal of controlled release : official journal of the Controlled Release Society·2025
Same journal

Continuous tracking of aortic aneurysm diameter with peripheral pulse waves: a computational framework combining sequential Markov chain Monte Carlo with Kalman filtering.

Physiological measurement·2026
Same journal

The 2026 global roadmap for textile-integrated wearable technologies in health.

Physiological measurement·2026
Same journal

Augmenting single-lead ECG interpretation through QRS waveform decomposition and rotation.

Physiological measurement·2026
Same journal

Dynamic Beat-to-Beat Blood Pressure Estimation using a Multi-modal Wearable Deep Learning Approach.

Physiological measurement·2026
Same journal

Dual warm-start fusion versus attention-based fusion in low-label ECG-PCG classification: a controlled ablation study.

Physiological measurement·2026
Same journal

Inter-patient multi-label ECG classification via low-rank adaptation fine-tuned large language models with dynamic graph convolutional network.

Physiological measurement·2026
See all related articles

Related Experiment Video

Updated: May 8, 2026

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
07:11

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis

Published on: August 19, 2021

Improved Cole parameter extraction based on the least absolute deviation method.

Yuxiang Yang1, Wenwen Ni, Qiang Sun

  • 1Department of Precision Instrumentation Engineering, Xi'an University of Technology, Xi'an, People's Republic of China.

Physiological Measurement
|September 12, 2013
PubMed
Summary
This summary is machine-generated.

This study introduces a more robust method for extracting Cole parameters from bioimpedance spectroscopy data. The least absolute deviation (LAD) method outperforms traditional least-squares (LS) fitting, especially with noisy or outlier-affected data.

More Related Videos

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
06:50

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression

Published on: November 8, 2019

Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
10:25

Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements

Published on: June 28, 2016

Related Experiment Videos

Last Updated: May 8, 2026

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
07:11

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis

Published on: August 19, 2021

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
06:50

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression

Published on: November 8, 2019

Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
10:25

Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements

Published on: June 28, 2016

Area of Science:

  • Biomedical Engineering
  • Electrical Engineering
  • Biophysics

Background:

  • Bioimpedance spectroscopy (BIS) relies on the Cole function for data analysis.
  • Accurate Cole parameter extraction (R0, R∞, α, τ) is crucial for assessing tissue status.
  • Traditional least-squares (LS) fitting is sensitive to noise and outliers, lacking robustness.

Purpose of the Study:

  • To propose an improved method for Cole parameter extraction using the least absolute deviation (LAD).
  • To evaluate the robustness of the LAD method compared to the LS method.

Main Methods:

  • Cole parameter extraction from bioimpedance spectroscopy data.
  • Comparison of least absolute deviation (LAD) fitting with least-squares (LS) fitting.
  • Simulation experiments under conditions of outliers and random noise.

Main Results:

  • The LAD method demonstrated superior robustness compared to the LS method.
  • LAD performance was significantly better when data contained outliers, noise, or both.
  • The proposed LAD method is a more reliable alternative for Cole parameter extraction.

Conclusions:

  • The least absolute deviation (LAD) method offers enhanced robustness for Cole parameter extraction in bioimpedance spectroscopy.
  • LAD is a valuable alternative to LS fitting, particularly for noisy or outlier-contaminated datasets.
  • This improved method enhances the reliability of assessing biological tissue status via BIS.