Diagnostic accuracy of three different methods of temperature measurement in acutely ill geriatric patients
Katrin Singler1, Thomas Bertsch, Hans Juergen Heppner
1Department of Geriatric Medicine, Nuremberg Hospital, Nuremberg, Germany.
Objective:
we examined the diagnostic accuracy of different methods of body temperature measurement to diagnose infection in geriatric patients presenting to the emergency department (ED).
Methods:
this observational study was done in consecutive patients ≥75 years old presenting to the ED. Body temperature was determined by tympanal thermometry, temporal artery thermometry and rectal temperature measurement. Adjudicated final diagnosis of infection was done by two experts including patient history, clinical and laboratory findings as well as radiographic studies.
Results:
a total of 427 patients were included in the data analysis (age: 82.7 ± 5.1 years). Infection was present in 105 patients (24.6%). Respiratory rate, heart rate and body temperature were significantly higher in patients with infection, blood pressure was lower (P < 0.01). Body temperature measured by tympanal and temporal artery thermometry was correlated with rectal thermometry. Body temperature was significantly higher in patients with infection compared with those without infection independent of the method of body temperature measurement (P < 0.001). The diagnostic accuracy for infection quantified by the area under curve (AUC) was comparable among rectal [AUC: 0.72 (95% CI: 0.65-0.80)] and tympanal thermometry [AUC: 0.73 (95% CI: 0.66-0.81)], but significantly lower in temporal artery thermometry [AUC: 0.65 (95% CI: 0.57-0.73; P < 0.001)]. Compared with rectal measurement tympanal thermometry showed a higher bias than temporal artery thermometry (0.54 versus 0.03°C), while its limits of agreement were more narrow (-0.14 to 1.21°C versus -0.94-1.01°C).
Conclusion:
diagnostic accuracy for the identification of infection was comparable among tympanal and rectal thermometry and lower for temporal artery thermometry. Different cut-off points should be used to identify infection using tympanal (37.3°C) or rectal (37.9°C) thermometry. In general, temperature measurement is an insensitive method to identify geriatric patients with infection. Registration number clinicaltrials.com: KSMC-tempger-1.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...