A calibration strategy in bioimaging trace elements in rat brain tissue by LA ICP-TOF-MS method
Kamil Jurowski1, Stanislaw Walas, Wojciech Piekoszewski
1Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Krakow, Poland.
This study introduces a novel calibration procedure for trace element analysis using Laser Ablation Inductively Coupled Plasma Time of Flight Mass Spectrometry (LA ICP-TOF-MS). The method enhances accuracy in solid sample analysis, particularly in biological tissues.
Area of Science:
- Analytical Chemistry
- Mass Spectrometry
- Trace Element Analysis
Background:
- Calibration is crucial but often inadequately addressed in analytical procedures.
- Existing nomenclature for calibration methods lacks clarity and respect.
- Accurate calibration is vital for reliable trace element determination.
Purpose of the Study:
- To develop and present a refined calibration procedure for analytical methods.
- To address issues with current calibration nomenclature.
- To improve the accuracy of trace element determination in complex matrices.
Main Methods:
- Developed a new classification for calibration dependence reconstruction and data transformation.
- Applied the method of standard addition using biological tissue samples as standards.
- Utilized Laser Ablation Inductively Coupled Plasma Time of Flight Mass Spectrometry (LA ICP-TOF-MS).
Main Results:
- Demonstrated the effectiveness of the developed calibration procedure.
- Successfully determined trace elements in rat brain tissues.
- Showcased the procedure's utility for solid sample analysis.
Conclusions:
- The novel calibration procedure is effective for trace element analysis in biological solid samples.
- The developed method offers an improvement over existing calibration techniques.
- The work provides a valuable contribution to analytical methodology for complex matrices.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
Published on: May 4, 2020
14:53In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis
Published on: February 3, 2018
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences