Review of the catalytic voltammetric determination of titanium traces
Abstract:
Catalytic and catalytic adsorptive stripping voltammetry are some of the most sensitive analytical methods. A review of various catalytic and catalytic adsorptive systems of titanium and their use in voltammetric analysis is presented. The mechanisms of catalytic reactions are discussed in detail. In addition to a survey of literature (91 references), catalytic polarographic, voltammetric and catalytic adsorptive stripping voltammetric determination of titanium traces at liquid mercury and metallic films electrodes are discussed briefly. Moreover, the application of the redox systems Ti(IV)/Ti(III) for the indirect determination of voltammetrically inactive oxidizers participating in catalytic reactions (e.g. chlorates) and voltammetrically inactive ligands (e.g. organic acids and thiocyanates) is also presented.
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...