Measurement of the D*(2010)+ meson width and the D*(2010)+ - D0 mass difference

J P Lees1, V Poireau, V Tisserand

  • 1Laboratoire d'Annecy-le-Vieux de Physique des Particules (LAPP), Université de Savoie, CNRS/IN2P3, F-74941 Annecy-Le-Vieux, France.

Physical Review Letters
|October 1, 2013
PubMed
Summary

This study precisely measured the mass difference and natural linewidth of the D*(2010)+ meson transition to D0 and a pion. The results offer significant improvements in precision over previous measurements.

Related Concept Videos

Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Gravitational Potential Energy for Extended Objects01:07

Gravitational Potential Energy for Extended Objects

Consider a system comprising several point masses. The coordinates of the center of mass for this system can be expressed as the summation of the product of each mass and its position vector divided by the total mass:
Reduced Mass Coordinates: Isolated Two-body Problem01:12

Reduced Mass Coordinates: Isolated Two-body Problem

In classical mechanics, the two-body problem is one of the fundamental problems describing the motion of two interacting bodies under gravity or any other central force. When considering the motion of two bodies, one of the most important concepts is the reduced mass coordinates, a quantity that allows the two-body problem to be solved like a single-body problem. In these circumstances, it is assumed that a single body with reduced mass revolves around another body fixed in a position with an...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
Gravitation Between Spherically Symmetric Masses01:14

Gravitation Between Spherically Symmetric Masses

The gravitational potential energy between two spherically symmetric bodies can be calculated from the masses and the distance between the bodies, assuming that the center of mass is concentrated at the respective centers of the bodies.