Related Experiment Video
Updated: May 7, 2026

16:40
A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Terminology, characterization, and measurement of ICD defibrillation impedance
1Florida Heart Rhythm Institute and Tampa General Hospital, Tampa, FL, USA.
Journal of Electrocardiology
|October 1, 2013
Abstract
No abstract available in PubMed .
Related Concept Videos
Impedances and Admittance
In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
RLC Series Circuits: Impedance
When current flow is opposed in a DC or AC circuit, it is referred to as resistance or impedance, respectively. Impedance plays a key role in determining the performance of AC circuits. It is represented by Z, which is a combination of resistance and reactance, and depends upon the angular frequency, measured in ohms.
Thus, the magnitude of the impedance is given by the following equation,
Thus, the magnitude of the impedance is given by the following equation,
Bode Plots Construction
The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
Line Protection with Impedance Relays
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
Impedance Combination
Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the voltage division...
Insulation Coordination
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
