Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
15.7K
Downsizing of coreless coils for transcutaneous energy transmission in implantable devices - improvement of coupling
Abstract:
Transcutaneous energy transmission is useful for improving patient quality of life and for supplying energy to implantable devices noninvasively. To supply highly efficient energy transmission through the skin, it is necessary to increase the coupling factor between the coils and increase the inductance of each coil. In this study, the optimal shape required for the coils to increase the coupling factor was investigated.
Related Concept Videos
Transdermal Drug Delivery Systems
243
Transdermal drug delivery systems (TDDS) enable the controlled release of drugs across the skin into systemic circulation. They are particularly advantageous for drugs with short half-lives or narrow therapeutic indices, as they maintain consistent plasma concentrations and reduce the risk of subtherapeutic or toxic levels.TDDS are categorized into monolithic, reservoir, and mixed systems. Monolithic systems embed the drug in a polymer matrix, where diffusion governs release. Reservoir systems...
243
Induced Electric Fields: Applications
2.7K
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
2.7K
Energy Stored In A Coaxial Cable
2.1K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field...
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field...
2.1K
Electrodes: Overview
2.5K
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
2.5K
Energy Losses in Transformers
1.6K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.6K
Energy Stored in Inductors
1.2K
An inductor is ingeniously crafted to accumulate energy within its magnetic field. This field is a direct result of the current that meanders through its coiled structure. When this current maintains a steady state, there is no detectable voltage across the inductor, prompting it to mimic the behavior of a short circuit when faced with direct current.
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...
1.2K