Related Experiment Video
Updated: Sep 23, 2026

Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
Response-separation-guided line impedance stabilization network-probe apparatus for fixed-plane in-circuit impedance
Guozheng Zhang1, Yuyu Zhu1, Haoran Li1
1Southwest University of Science and Technology, Mianyang 621010, China.
Abstract:
Sensitive in-circuit impedance measurement is often limited by the response separation between practical short and open standards after receiving-network, cable, and fixture residuals are included. We present a response-separation-guided line impedance stabilization network (LISN)-probe apparatus for fixed-plane impedance extraction. The calibrated asymmetric LISN-probe combination uses a LISN for isolation and coupling, while the current-probe interface lowers equivalent receiving-port impedance. An equivalent-port model, short-open-load (SOL) calibration at a fixed device-under-test (DUT) plane, and a response-noise-aware local impedance-resolution proxy separate global end point-response contrast from one-standard-deviation noise-equivalent local impedance fluctuation. At 1 MHz, measured short-open response-separation gains are 24.6 dB over the dual-LISN path and 33.6 dB over the dual-probe-plus-LISN path, corresponding to ∼17-fold and 48-fold increases in global short-open response ratio. Local fluctuation is evaluated independently through the SOL-inversion Jacobian and measured repeated-DUT-response covariance. Apparatus-level validation is restricted to 0.5-10 MHz. Passive-standard tests show that increased response separation is not a universal accuracy improvement: the LISN-probe method gives 95th-percentile errors of 1.5% and 8.1% for the 255 Ω and 1.5 kΩ standards, while the dual-LISN path is preferable at 5 Ω. Probe and LISN fits give normalized root-mean-square errors of 2.72% and 2.62%, respectively. The apparatus also resolves current-dependent magnetic-component impedance changes, with a series-equivalent decomposition quantifying resistance and inductance reductions. Results establish the sensitivity benefit, measurement-performance boundary, and validated frequency range of this fixed-plane apparatus, without claiming a general modal electromagnetic-interference compliance measurement.
Related Concept Videos
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Lossless Lines
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
RLC Series Circuits: Impedance
Thus, the magnitude of the impedance is given by the following equation,
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Mass Analyzers: Common Types

