Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Mechanical Systems01:22

Mechanical Systems

904
Mechanical systems are analogous to to electrical networks where springs and masses play similar roles to inductors and capacitors, respectively. A viscous damper in mechanical systems functions similarly to a resistor in electrical networks, dissipating energy. The forces acting on a mass in such systems include an applied force in the direction of motion, counteracted by forces from the spring, a viscous damper, and the mass's acceleration. This interplay of forces is mathematically...
904
Development of the Limb Synovial Joints01:07

Development of the Limb Synovial Joints

5.0K
Joints form during embryonic development in conjunction with the formation and growth of the associated bones. The embryonic tissue that gives rise to all bones, cartilage, and connective tissues of the body is called mesenchyme.
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...
5.0K
Mechanical Efficiency of Real Machines01:14

Mechanical Efficiency of Real Machines

1.6K
The mechanical efficiency of a machine is a fundamental concept that describes how effectively a machine can convert input work into output work. According to this concept, the efficiency of a machine is equal to the ratio of the output work to the input work. An ideal machine, meaning a machine that has no energy losses, has an efficiency of one. This implies that the input work and the output work are equal.
However, in reality, no machine can be truly ideal, and all of them experience some...
1.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Neonatal blood glucose monitoring using glucose estimation by phase delay between oxy- and deoxyhemoglobin.

Pediatric research·2026
Same author

Third nationwide survey of bilirubin encephalopathy in preterm infants in Japan.

Brain & development·2026
Same author

Evaluation of the TB/pTP Ratio Using Refractometric Measurement of Plasma Total Protein in Neonates.

Pediatrics international : official journal of the Japan Pediatric Society·2026
Same author

Distribution of Lipoprotein(a) Levels Among Children with Elevated Low-Density Lipoprotein Cholesterol Identified Through Universal Pediatric Lipid Screening.

Journal of atherosclerosis and thrombosis·2026
Same author

Use of transcutaneous bilirubinometers in preterm infants in Japan.

Pediatrics international : official journal of the Japan Pediatric Society·2026
Same author

Publisher Correction: Association between hydrogen gas inhalation and cardiac output in an asphyxiated piglet model.

Scientific reports·2026

Related Experiment Video

Updated: May 7, 2026

An Application for Pairing with Wearable Devices to Monitor Personal Health Status
06:58

An Application for Pairing with Wearable Devices to Monitor Personal Health Status

Published on: February 3, 2022

2.7K

Development on smart suit for dairy work assistance.

Hiroyuki Nara, Takashi Kusaka, Takayuki Tanaka

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |October 11, 2013
    PubMed
    Summary

    This study introduces the "smart suit," a power-assist wearable designed to reduce fatigue in the elderly. By decreasing strain during daily tasks, it aims to enhance independence and social engagement for older adults.

    More Related Videos

    An Efficient Single—Person Technique for Milk Sampling from Laboratory Mice
    04:56

    An Efficient Single—Person Technique for Milk Sampling from Laboratory Mice

    Published on: March 28, 2025

    2.0K
    Enhancing the Development and Growth of Infant Cerebral Palsy Rats Using Selective Spinal Manipulations
    05:04

    Enhancing the Development and Growth of Infant Cerebral Palsy Rats Using Selective Spinal Manipulations

    Published on: February 2, 2024

    1.2K

    Related Experiment Videos

    Last Updated: May 7, 2026

    An Application for Pairing with Wearable Devices to Monitor Personal Health Status
    06:58

    An Application for Pairing with Wearable Devices to Monitor Personal Health Status

    Published on: February 3, 2022

    2.7K
    An Efficient Single—Person Technique for Milk Sampling from Laboratory Mice
    04:56

    An Efficient Single—Person Technique for Milk Sampling from Laboratory Mice

    Published on: March 28, 2025

    2.0K
    Enhancing the Development and Growth of Infant Cerebral Palsy Rats Using Selective Spinal Manipulations
    05:04

    Enhancing the Development and Growth of Infant Cerebral Palsy Rats Using Selective Spinal Manipulations

    Published on: February 2, 2024

    1.2K

    Area of Science:

    • Gerontology
    • Biomedical Engineering
    • Ergonomics

    Background:

    • Aging populations require innovative solutions for maintaining independence.
    • Fatigue and physical strain limit daily activities and social involvement for the elderly.
    • KEIROKA Technology focuses on fatigue reduction to improve quality of life.

    Purpose of the Study:

    • To develop and evaluate a power-assist suit, the "smart suit", for elderly individuals.
    • To enhance the quality of chores and occupations by reducing physical strain and tiredness.
    • To promote independent living and social involvement among the elderly population.

    Main Methods:

    • Development of the "smart suit" incorporating KEIROKA Technology.
    • Evaluation of the suit's effectiveness in dairy work assistance.
    • Measurement of electromyography (EMG) signals to assess muscle activity with and without the suit.

    Main Results:

    • The "smart suit" demonstrated a measurable effect on reducing physical strain during work.
    • EMG data indicated differences in muscle activation between wearing and not wearing the suit.
    • The technology shows potential for improving the physical capacity of elderly workers.

    Conclusions:

    • The "smart suit" shows promise in mitigating fatigue and strain for the elderly.
    • This technology can support independent living and social participation by enhancing work quality.
    • Further research is warranted to fully explore the benefits of power-assist suits in gerontology.