Screen printed flexible radiofrequency identification tag for oxygen monitoring
A Martínez-Olmos1, J Fernández-Salmerón, N Lopez-Ruiz
1ECsens, Department of Electronics and Computer Technology and ‡Department of Analytical Chemistry, Campus Fuentenueva, Faculty of Sciences, University of Granada , E-18071 Granada, Spain.
Abstract:
In this work, a radiofrequency identification (RFID) tag with an optical indicator for the measurement of gaseous oxygen is described. It consists of an O2 sensing membrane of PtOEP together with a full electronic system for RFID communication, all printed on a flexible substrate. The membrane is excited by an LED at 385 nm wavelength and the intensity of the luminescence generated is registered by means of a digital color detector. The output data corresponding to the red coordinate of the RGB color space is directly related to the concentration of O2, and it is sent to a microcontroller. The RFID tag is designed and implemented by screen printing on a flexible substrate for the wireless transmission of the measurement to a remote reader. It can operate in both active and passive mode, obtaining the power supply from the electromagnetic waves of the RFID reader or from a small battery, respectively. This system has been fully characterized and calibrated including temperature drifts, showing a high-resolution performance that allows measurement of very low values of oxygen content. Therefore this system is perfectly suitable for its use in modified atmosphere packaging where the oxygen concentration is reduced below 2%. As the reading of the O2 concentration inside the envelope is carried out with an external RFID reader using wireless communication, there is no need for perforations for probes or wires, so the packaging remains completely closed. With the presented device, a limit of detection of 40 ppm and a resolution as low as 0.1 ppm of O2 can be reached with a low power consumption of 3.55 mA.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...


