Related Experiment Video
Updated: May 7, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Measuring and managing radiologist workload: a method for quantifying radiologist activities and calculating the
Sharyn L S MacDonald1, Ian A Cowan, Richard A Floyd
1Radiology Department, Christchurch Hospital, Christchurch, New Zealand.
Introduction:
Accurate and transparent measurement and monitoring of radiologist workload is highly desirable for management of daily workflow in a radiology department, and for informing decisions on department staffing needs. It offers the potential for benchmarking between departments and assessing future national workforce and training requirements. We describe a technique for quantifying, with minimum subjectivity, all the work carried out by radiologists in a tertiary department.
Methods:
Six broad categories of clinical activities contributing to radiologist workload were identified: reporting, procedures, trainee supervision, clinical conferences and teaching, informal case discussions, and administration related to referral forms. Time required for reporting was measured using data from the radiology information system. Other activities were measured by observation and timing by observers, and based on these results and extensive consultation, the time requirements and frequency of each activity was agreed on. An activity list was created to record this information and to calculate the total clinical hours required to meet the demand for radiologist services.
Results:
Diagnostic reporting accounted for approximately 35% of radiologist clinical time; procedures, 23%; trainee supervision, 15%; conferences and tutorials, 14%; informal case discussions, 10%; and referral-related administration, 3%. The derived data have been proven reliable for workload planning over the past 3 years.
Conclusions:
A transparent and robust method of measuring radiologists' workload has been developed, with subjective assessments kept to a minimum. The technique has value for daily workload and longer term planning. It could be adapted for widespread use.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Quantifying Work
Estimation of the Physical Quantities
Biological Effects of Radiation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...