Sensitivity of palm print, modified mallampati score and 3-3-2 rule in prediction of difficult intubation
Ata Mahmoodpoor1, Hassan Soleimanpour, Kavous Shahsavari Nia
1Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran.
Background:
This study evaluated the performance of modified Mallampati score, 3-3-2 rule and palm print in prediction of difficult intubation.
Methods:
In a prospective descriptive study, data from 500 patients scheduled for elective surgery under general anesthesia were collected. An anesthesiologist evaluated the airway using mentioned tests and another anesthesiologist evaluated difficult intubation. Laryngoscopic views were determined by Cormack and Lehane score. Grades 3 and 4 were defined as difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and Youden index were determined for all tests.
Results:
Difficult intubation was reported in 8.9% of the patients. There was a significant correlation between body mass index and difficult intubation (P : 0.004); however, other demographic characteristics didn't have a significant correlation with difficult intubation. Among three tests, palm print was of highest specificity (96.46%) and modified Mallampati of highest sensitivity (98.40%). In a combination of the tests, the highest specificity, sensitivity and Youden index were observed when using all three tests together.
Conclusions:
Palm print has a high specificity for prediction of difficult intubation, but the best way for prediction of difficult intubation is using all three tests together.
More Related Videos
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation