Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Applications of EMF Measurements01:26

Applications of EMF Measurements

122
Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and...
122
Electromagnetic Fields01:30

Electromagnetic Fields

1.8K
Electric fields generated by static charges, often referred to as electrostatic fields, are characteristically different from electric fields created by time-varying magnetic fields. While the former is a conservative field, implying that no net work is done on a test charge if it goes around in a complete loop in the field, the latter is, by definition, not a conservative field; net work is done, and it is proportional to the rate of change of magnetic flux.
However, the observation of...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Socio-economic status as an environmental factor - incidence of underweight, overweight and obesity in adolescents from less-urbanized regions of Poland.

Annals of agricultural and environmental medicine : AAEM·2015
Same author

Bioelectromagnetic effects measurements - SAR and induced current.

Bio-medical materials and engineering·2015
Same author

Influence of quasi-spherical polarization on results of bioelectromagnetic studies.

Electromagnetic biology and medicine·2014
Same author

Uncertainity analysis of selected sources of errors in bioelectromagnetic investigations.

Bio-medical materials and engineering·2013
Same author

A new solution for biomedical experiments.

Electromagnetic biology and medicine·2013
Same author

[Bioelectromagnetic studies: an analysis of errors in evaluation of electromagnetic field exposure].

Medycyna pracy·2009

Related Experiment Video

Updated: May 6, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
06:43

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band

Published on: May 2, 2018

9.7K

Exposure systems for bioelectromagnetic experiments.

Tomasz Dlugosz1, Hubert Trzaska

  • 1Department of Telecommunication & Teleinformatics, Faculty of Electronics, Wroclaw University of Technology , Wroclaw , Poland.

Electromagnetic Biology and Medicine
|October 18, 2013
PubMed
Summary

Experimental discrepancies in bioelectromagnetics may stem from technical factors in exposure systems. Analyzing interactions between biological objects and equipment is crucial for accurate research findings.

Keywords:
Biomedical applications of radiationcomputational electromagneticselectromagnetic analysisexposure systemsmeasurement standards

More Related Videos

An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
09:29

An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing

Published on: May 13, 2020

13.5K
Brain State-dependent Brain Stimulation with Real-time Electroencephalography-Triggered Transcranial Magnetic Stimulation
08:50

Brain State-dependent Brain Stimulation with Real-time Electroencephalography-Triggered Transcranial Magnetic Stimulation

Published on: August 20, 2019

17.3K

Related Experiment Videos

Last Updated: May 6, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
06:43

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band

Published on: May 2, 2018

9.7K
An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
09:29

An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing

Published on: May 13, 2020

13.5K
Brain State-dependent Brain Stimulation with Real-time Electroencephalography-Triggered Transcranial Magnetic Stimulation
08:50

Brain State-dependent Brain Stimulation with Real-time Electroencephalography-Triggered Transcranial Magnetic Stimulation

Published on: August 20, 2019

17.3K

Area of Science:

  • Bioelectromagnetics
  • Biophysics
  • Experimental Methodology

Background:

  • Replication challenges persist in bioelectromagnetics research across different laboratories.
  • Variability in experimental outcomes is often attributed to differences in biological specimens, particularly in in vivo studies.

Purpose of the Study:

  • To highlight technical aspects of exposure systems influencing experimental results.
  • To investigate the role of mutual interactions between biological objects and exposure systems.
  • To emphasize the impact of polarization and exposure similarity on experimental outcomes.

Main Methods:

  • Focus on engineering principles of electromagnetic exposure systems.
  • Analysis of inter-object and object-system interactions.
  • Evaluation of polarization effects and exposure fidelity.

Main Results:

  • Technical factors within exposure systems can significantly impact experimental results.
  • Mutual interactions between biological objects and the exposure setup introduce variability.
  • Inconsistent polarization and exposure conditions lead to divergent outcomes.

Conclusions:

  • Standardizing technical aspects of exposure systems is essential for reproducible bioelectromagnetics research.
  • Understanding object-system and inter-object interactions is critical for interpreting experimental data.
  • Attention to technical details can prevent erroneous conclusions in bioelectromagnetic studies.